Skip to content

PLOSSYS Administrator


Here, you find possible solutions to problems that can occur with PLOSSYS Administrator when installing or running PLOSSYS Output Engine.


Username Contains Windows Domain Name

To remove the Windows Domain from the username, set the environment key REMOVE_WINDOWS_DOMAIN_FROM_USERNAME for ipp-checkin service to true and restart the ipp-checkin service.

For this fix, PLOSSYS Output Engine as of version 7.3.0 is required.


Flickering Browser When Opening PLOSSYS Administrator

If you cannot open the user interface, PLOSSYS Administrator, and the browser is flickering, the reason could be be one of the following situations:


Loading Browser When Opening PLOSSYS Administrator

If Loading... is the only thing you get when opening the user interface, PLOSSYS Administrator, the reason could be the following situation:

  • You do not have the permission to do anything with PLOSSYS Administrator. In the OIDC identity provider, check if you have a role assigned that has permissions for PLOSSYS Administrator.

Erroneous Job With Virtual Queue

With a virtual failover queue, all queues involved have to be configured in PLOSSYS Output Engine. Otherwise, the jobs for the virtual queue will terminate as erroneous.


Queue Does Not Respond

If a queue no longer responds and no longer prints, reactivate the queue by pausing and resuming it in PLOSSYS Administrator. When pausing the queue, all locks will be removed.


No Dashboard After Updating to 5.3.2

With PLOSSYS 5.3.2, the dashboard of PLOSSYS Administrator has been secured. In order that the user can see the dashboard, the dashbord area has to be specified in the ALLOWED_OIDC_CLIENTS key. For more information, refer to ALLOWED_OIDC_CLIENTS.


Back to top